smartctl 7.0 2018-12-30 r4883 [x86_64-linux-3.10.0-957.21.3.el7.x86_64] (local build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Fujitsu MHZ BK
Device Model:     FUJITSU MHZ2250BK G2
Serial Number:    K85ET9625FV4
LU WWN Device Id: 5 00000e 043b3c485
Add. Product Id:  DELL
Firmware Version: 8A22
User Capacity:    250,059,350,016 bytes [250 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 3f
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Mon Jul  8 21:35:00 2019 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  812) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 111) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x003f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   046    Pre-fail  Always       -       119531
  2 Throughput_Performance  0x0004   100   100   000    Old_age   Offline      -       33882636
  3 Spin_Up_Time            0x0003   100   100   025    Pre-fail  Always       -       2
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       36
  5 Reallocated_Sector_Ct   0x0033   100   100   024    Pre-fail  Always       -       0 (2000 0)
  7 Seek_Error_Rate         0x000e   100   100   000    Old_age   Always       -       1190
  8 Seek_Time_Performance   0x0004   100   100   000    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   001   001   000    Old_age   Always       -       81676
 10 Spin_Retry_Count        0x0012   100   100   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       36
191 G-Sense_Error_Rate      0x0012   100   100   000    Old_age   Always       -       21
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       20
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       20 (Min/Max 17/50)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       -       316
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0 (0 7014)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   253   000    Old_age   Always       -       8
200 Multi_Zone_Error_Rate   0x000e   100   100   000    Old_age   Always       -       9964
201 Soft_Read_Error_Rate    0x0010   100   100   000    Old_age   Offline      -       0
203 Run_Out_Cancel          0x0002   100   100   000    Old_age   Always       -       429541685302
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       19653
240 Head_Flying_Hours       0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 1
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 37911 hours (1579 days + 15 hours)
  When the command that caused the error occurred, the device was doing SMART Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 03 c5 06 7d 40  Error: WP at LBA = 0x007d06c5 = 8193733

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 08 20 a0 7c 34 40 00  26d+19:16:30.697  WRITE FPDMA QUEUED
  61 01 18 90 ab 00 40 00  26d+19:16:29.226  WRITE FPDMA QUEUED
  61 08 10 98 a2 73 40 00  26d+19:16:27.452  WRITE FPDMA QUEUED
  61 10 00 50 ca f4 40 00  26d+19:16:27.452  WRITE FPDMA QUEUED
  60 01 08 b0 ff 02 40 00  26d+19:16:27.449  READ FPDMA QUEUED

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%         2         -
# 2  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.